The Mobile Setup Analyser checks the installation and setup of maintool mobile and shows a suggested solution for every error found. Run the check after the setup and after every change to Anvaigo users or synchronization packages to find setup errors before the users synchronize.
Prerequisites
- maintool mobile is installed, see Install and set up maintool mobile.
- You have the maintool App Setup permission set (
GLI Mob Setup).
Start the check
- Use the search (Alt+Q) to find Mobile Setup Analyser. Alternatively, choose the Mobile Setup Analyser action in the Mobile Setup.
- Choose the Run Test action.
- If there are results from an earlier check, maintool asks When the analysis is started, the current log is deleted. Continue? Confirm with Yes.
- Read the results and fix the reported errors.
- Run the check again until no more errors are reported.
Read the result
Each line of the analysis has these columns:
| Column | Content |
| Log | Result of the check, for example The synchronization packet "MAINTOOL" is not active. |
| Solution | Suggestion for fixing the error, for example which field you must fill in. |
| Test DateTime | Time of the check. |
| Error | Success (highlighted in green) or Error (highlighted in red). Lines without a value mark the start and end of a check area and are shown in bold. |
What is checked
| Check area | Check | If an error is reported |
| General | The app configuration of maintool mobile has been imported (MAINTOOL main menu exists). |
Import the app configuration, see Import and update the app configuration. |
| General | Synchronization packages exist, and all except MAINTOOL HISTORY are active. |
Activate the reported package in the Anvaigo setup; if all packages are missing, import the app configuration again. |
| General | The language codes DEU, DES, DEA, ENG and ENU exist on the Languages page. |
Create the missing language code. |
| General | The base unit of measure of every resource that is assigned to an Anvaigo user has a Mobile Unit of Measure. It is needed for time recording in the app. | Enter the Mobile Unit of Measure for the reported unit of measure, see Prepare master data for maintool mobile. |
| Anvaigo setup | The Anvaigo license is valid. | Contact support, see maintool Support & Ticket System. |
| Anvaigo users | There is at least one Anvaigo user. Each one has synchronization packages assigned, the MAINTOOL main menu and a default company, the Relation Type field contains Resource and the resource in the Relation Code field exists. |
Complete the information on the reported Anvaigo user, see Set up Anvaigo users. |
| Stock Receipts | No stock receipt recorded in maintool mobile has a received quantity that is greater than the Qty. to Receive of the purchase line. Otherwise, the analysis reports, for example, Purchase Order 106001 has already been received with 5 PCS. | Cancel the stock receipt named in the Solution column, see Stock receipt. |
Delete test results
The Delete Test Results action removes all lines of the last check without asking for confirmation.
Notes and limitations
- The analysis does not change the setup. You fix errors yourself on the pages mentioned.
- The analysis does not check the settings of the mobile users, for example department, journals and number series. maintool checks these when the respective function is turned on, see Set up mobile users and user groups.
Related articles