Search for technical specifications does not find values

  • Updated

You use Search for Technical Specifications to look for a value that is in the data sheet of an object, but the object does not appear in the result list. Or the search stops with a message. You find the most common causes and solutions here.

How the search works

  • The search reads a separate copy of the data sheet content, which maintool updates with every change to a data sheet. There is a separate column for each data type.
  • Which column is searched depends on the Data Type that the technical specification has at the time of the search.
  • The Type field narrows down the object type. If you open the search from an object card, it is preset with this object type.

Messages and causes

Message or symptom Cause Solution
Objects of a certain type never appear. Another object type is selected in the Type field, for example because you opened the search from an object card. Select All or the appropriate object type in the Type field and choose Find again.
With several criteria, objects that only meet some of the criteria are missing. The Logic Operator is AND. maintool then only shows objects that all filters apply to. Select OR in the Query Details or remove criteria.
A text value is not found although it is in the data sheet. For technical specifications with the data type Text, the filter compares the whole content. Part of the text is not enough. Use wildcards, for example *Motor*.
After changing the Data Type of a technical specification, the search no longer finds the values. The copy of the data sheet content still contains the values in the old data type. The search looks in the new data type. Check whether the content in the data sheets matches the new data type. Then run Mirror Data Sheets manually for the affected object types, see Search for technical specifications.
The results generally do not match the data sheets, for example hits are missing or old values appear. The copy of the data sheet content is no longer up to date with the data sheets. Run Mirror Data Sheets manually for the affected object types and search again.
The search query contains an error. The text in the Find What field does not have the format Code: Filter, for example the colon is missing. Define the criteria with the … button in the Query Details instead of writing them by hand.
You may not mix AND / OR. The Find What field contains both & and |. Use only one of the two operators. In the Query Details, the Logic Operator always applies to all lines.
Error message about the technical specification when searching or in the Query Details The code before the colon is not an existing technical specification. Select the technical specification from the list in the Query Details.
Error message about the Type field when you accept a hit with OK The search was opened from an object card, and the hit belongs to another object type. Open the hit with Show.

Related articles

Related to

Was this article helpful?

0 out of 0 found this helpful

Have more questions? Submit a request