You use Search for Technical Specifications to look for a value that is in the data sheet of an object, but the object does not appear in the result list. Or the search stops with a message. You find the most common causes and solutions here.
How the search works
- The search reads a separate copy of the data sheet content, which maintool updates with every change to a data sheet. There is a separate column for each data type.
- Which column is searched depends on the Data Type that the technical specification has at the time of the search.
- The Type field narrows down the object type. If you open the search from an object card, it is preset with this object type.
Messages and causes
| Message or symptom | Cause | Solution |
| Objects of a certain type never appear. | Another object type is selected in the Type field, for example because you opened the search from an object card. | Select All or the appropriate object type in the Type field and choose Find again. |
| With several criteria, objects that only meet some of the criteria are missing. | The Logic Operator is AND. maintool then only shows objects that all filters apply to. | Select OR in the Query Details or remove criteria. |
| A text value is not found although it is in the data sheet. | For technical specifications with the data type Text, the filter compares the whole content. Part of the text is not enough. | Use wildcards, for example *Motor*. |
| After changing the Data Type of a technical specification, the search no longer finds the values. | The copy of the data sheet content still contains the values in the old data type. The search looks in the new data type. | Check whether the content in the data sheets matches the new data type. Then run Mirror Data Sheets manually for the affected object types, see Search for technical specifications. |
| The results generally do not match the data sheets, for example hits are missing or old values appear. | The copy of the data sheet content is no longer up to date with the data sheets. | Run Mirror Data Sheets manually for the affected object types and search again. |
| The search query contains an error. | The text in the Find What field does not have the format Code: Filter, for example the colon is missing. | Define the criteria with the … button in the Query Details instead of writing them by hand. |
| You may not mix AND / OR. | The Find What field contains both & and |. |
Use only one of the two operators. In the Query Details, the Logic Operator always applies to all lines. |
| Error message about the technical specification when searching or in the Query Details | The code before the colon is not an existing technical specification. | Select the technical specification from the list in the Query Details. |
| Error message about the Type field when you accept a hit with OK | The search was opened from an object card, and the hit belongs to another object type. | Open the hit with Show. |
Related articles
- Search for technical specifications
- Maintain the data sheet of an object
- Create a technical specification
Related to