With data sheets, you record technical data such as power, year of construction or manufacturer for component addresses, mounting positions, technical components and vehicles. You can later search these values across all objects with Search for Technical Specifications. This article explains the terms, the data types and the order of the setup.
Terms
| Term | Meaning |
| Unit of measure | Unit of a value, for example kW or °C. You maintain units of measure on the standard Business Central page Units of Measure. |
| Range of values | Selection list of fixed values with a data type, for example a list of motor manufacturers. A range of values is optional. |
| Technical specification | A property you want to record, for example "Power electric motor". It defines the Data Type and optionally a unit of measure and a range of values. A technical specification itself does not contain a value. |
| Data sheet template | A set of several technical specifications, optionally with a Default Value per line, for example for all elevators of one type. |
| Data sheet | The list of technical specifications of a single object with the actual Content. A data sheet is created from a data sheet template or by direct entry. |
Example
For the elevators of one type, you create the data sheet template AUFZUG-T1. It contains the technical specifications load capacity (Decimal, unit kg), manufacturer (Code with a range of values of the manufacturers), year of construction (Integer) and acceptance date (Date). For the manufacturer, you enter a default value because all elevators of this type come from the same manufacturer. When you assign the template to an elevator, maintool copies the lines with the default value to its data sheet. You enter the other values per elevator.
Data types
The Data Type of the technical specification defines which entries maintool accepts in the data sheet, in the default value and in the values of a range of values. maintool rejects an entry that does not match the data type.
| Data type | Allowed entry | Example |
| Integer | whole number | Year of construction |
| Decimal | number with decimal places | Power in kW |
| Text | any text | Remark on the installation site |
| Code | text, maintool saves it in upper case | Type designation |
| Boolean | Yes or No | Accepted |
| Date | date | Commissioning |
| DateTime | date with time | Acceptance date and time |
| Time | time | Acceptance time |
You cannot assign a range of values to a technical specification with the data type Boolean.
Assignment fields
Technical specifications and data sheet templates have the fields Component Address Group, Component Group, Classification, Type and Construction Type (on the technical specification with the suffix Code, for example Classification Code). They only narrow down the selection lists:
- Data sheet template on the object: On a component address, maintool offers templates with the same Component Address Group and templates without a group. On a technical component, maintool offers templates whose Component Group, Classification, Type and Construction Type match the component or are empty. On mounting positions and vehicles, all templates are available.
- Technical specification in a data sheet template: If an assignment field is filled in the template, maintool only offers technical specifications with exactly the same value. Technical specifications without a value in this field are then not shown.
- Technical specification directly in the data sheet: On a component address, technical specifications with the same group or without a group are shown; on a technical component, those whose Classification Code, Component Group Code and Type Code match or are empty. On mounting positions and vehicles, all technical specifications are shown.
You can still enter a code directly that is not in the selection list. Component Address Group and the other four fields are mutually exclusive: If the group is filled, the other fields are locked and vice versa.
Order of the setup
- Create units of measure, if not yet available, and create ranges of values if needed, see Create ranges of values.
- Create technical specifications, see Create a technical specification.
- Create data sheet templates and assign them to the objects, see Create and assign data sheet templates.
- Enter the values in the data sheet of the object, see Maintain the data sheet of an object.
- Find objects by their values, see Search for technical specifications.
Before you start entering data, decide which specifications you need per object type and with which data type. This avoids duplicate technical specifications and later corrections in many data sheets.
Notes and limitations
- A data sheet does not stay linked to the template. Later changes to a template do not change existing data sheets.
- maintool always reads Description and Unit of Measure Code in the data sheet from the technical specification. If you change them there, you see the new values in all data sheets.
Related articles
- Create a technical specification
- Create ranges of values
- Create and assign data sheet templates
- Maintain the data sheet of an object
- Search for technical specifications
- Search for technical specifications does not find values
- Technical facility management overview
Related to