Equipment structure: errors when assigning mounting positions and levels

  • Updated

You want to place or move a component address or a technical component in the equipment structure, or assign a mounting position to a component address, but maintool refuses the change or a field is locked. Here you find the rules of the equipment structure and the solution for the most common messages.

Rules of the equipment structure

  • Component addresses and technical components have at most 8 levels. When you move an object, its whole substructure counts.
  • You only enter the Component Address Group on the component address of the top level. All sub-component addresses take it over.
  • A mounting position can be assigned to several component addresses, but only to one per Component Address Group.
  • A technical component is either under another component (Component from), in a mounting position (Mounting Position No.) or in a vehicle (Component from Vehicle No.), never in several at the same time.
  • You can only change the installation location of a technical component on the card as long as it has the Assignment Installation.

Messages and causes

Message or symptom Cause Solution
Component Address from can not be Component Address from himself. or Component from can not be Technical Component from himself. You selected the object itself or one of its own sub-objects as the higher-level object. Select a higher-level object outside the object's own substructure.
The maximum number of levels is 8. or The maximum number of 8 levels is exceeded in …. The new position and the levels below it add up to more than 8 levels. Place the object higher up or reduce the depth of the substructure.
The Mounting Position No. … is already used in the Component Address Group …. The mounting position is already assigned to another component address of the same group. This also applies to component addresses without a group: the group in the message is then empty. Delete the existing assignment (Mounting Positions action on the component address or Component Adresses action on the mounting position) and create the new one. If the mounting position is to appear in a further view, assign it to a component address of another group.
The Mounting Position … ist already connected to Component Address Group …. You move a component address to another group (with Component Address from or by changing the group). One of its mounting positions is already assigned to another component address in the new group. Delete one of the two mounting position assignments and then move the component address.
The Component Address Group field cannot be edited, or an error message about the Component Address from field appears. The component address is a sub-component address. The group comes from the top level. Change the group on the component address of the top level (see Main Component Address). maintool passes it on to all levels below.
After clearing Component Address from, the Component Address Group is empty and the Equipment Structure action is not available. The component address is now on the top level. maintool clears the group, also for its sub-component addresses. Enter the Component Address Group on the component address.
You can not change the value of …, because there is at least one Object Monitoring Line, where the counter value is posted through inheritance. In the structure, an object monitoring line of the counter type takes its value from an object on another level (Inherit Actual Value from No.). Moving the object would break this link. First remove the inheritance in the object monitoring line, see Link a technical object to an object monitoring template. Then move the object and set up the inheritance again if needed.
On the Technical Component Card, Component from, Mounting Position No. or Component from Vehicle No. is locked. One of the three fields is already filled. maintool then locks the other two. Clear the filled field and then enter the new installation location.
The Position field cannot be edited. Position defines the order within a mounting position and is only available with Mounting Position No.. Assign the component to a mounting position. Under another component, use a component place instead.
Assignment has to be Installation for Tech. Component … The history of the component has already been started. You then no longer change the installation location on the card. Move the component in the technical component journal, see Install, remove and relocate a technical component.

Related articles

Related to

Was this article helpful?

0 out of 0 found this helpful

Have more questions? Submit a request