Component addresses form the levels of your equipment structure, for example plant, plant section and assembly. You assign the component address of the top level to a component address group, and all further ones to a parent component address. This guide shows how to create a component address and place it in the structure.
Prerequisites
- In the Technical Facility Management Setup (Numbering FastTab), a number series is specified in the Component Adress Nos. field. If you want to enter the number manually, the number series must allow Manual Nos. (see Set up technical facility management).
- For component addresses of the top level, the appropriate component address group exists (see Set up master data for technical facility management).
Create a component address
- Search for Component Addresses and open the list.
- Choose New. The Component Address Card opens.
- In the No. field, enter the code of the component address (maximum 20 characters). If you leave the field blank, maintool assigns the number from the number series as soon as you move to the next field.
- In the Description field, enter the name (maximum 100 characters). maintool copies it to the Search Description; you can change the search description afterwards.
- Place the component address in the structure:
- top level: select the group in the Component Address Group field.
- below: select the parent component address in the Component Address from field.
- If required, fill in further fields (see below).
What happens when you place the component address
Top level
- A component address without Component Address from is on level 1. You can only enter or change the Component Address Group here; maintool passes it on to all sublevels.
- Without a Component Address Group, the component address does not appear in any structure, and the Equipment Structure action is not available.
Lower levels
- With Component Address from, the component address takes over the Component Address Group and the Main Component Address of the parent component address. The Component Address Group field can then no longer be edited.
- A structure has a maximum of 8 levels. A component address cannot be placed below itself or below one of its sub-component addresses.
- maintool takes over the Customer No., the Locality Code (if Passon Location is enabled above and Inherit Location below) and the Operating Status (if Pass on Operating Status is enabled above and Inherit from Operating Status below) from the parent component address.
Move a component address
If you change Component Address from, the component address moves to the new position together with all sub-component addresses and the assigned mounting positions. If you clear the field, it becomes the top level; the group is cleared in the process, and you have to select it again.
Further fields
| Field | Meaning |
| Global dimensions (captioned with the name of the dimension, e.g. Department Code) | Default dimensions of the component address. You maintain further dimensions with the Dimensions action. maintool takes them over into work orders for this component address; if it has no default dimensions, those of the parent component address apply. |
| Data Sheet Template | Copies the lines of the template to the data sheet of the component address. You can select templates of the same component address group and templates without a group. See Create and assign data sheet templates. |
| Customer No. | Customer for whom the equipment is maintained. Is passed on to subordinate component addresses, assigned mounting positions and their technical components. |
| Locality Code, Inherit Location, Passon Location | Location address of the component address and how it is passed on in the structure, see Locations of technical objects. |
| Operating Status, Inherit from Operating Status, Pass on Operating Status | Operating condition of the component address and how it is passed on in the structure (available from version 20261000.0), see Operating status for technical objects. |
| Blocked | For blocked objects, you cannot post performance characteristics, among other things, and maintool does not create work orders from time schedules for them. |
| Barcode / QR Code | Code on the label of the object. In the work order request for phone and tablet, users can find the object by this code. |
Result
The component address is part of the structure of its component address group. Check its position with the Equipment Structure action in the Equipment Information Center. Next, assign mounting positions to the component address.
Notes and limitations
- A mounting position may only be assigned to one component address per component address group. If you move a component address to a group in which one of its mounting positions is already assigned, maintool rejects the change.
- If an object monitoring line inherits its counter reading from another object of the structure, you cannot change Component Address from. Remove the inheritance first.
- You create several similar component addresses faster by copying, see Duplicate technical objects.
Related articles
- Plan the equipment structure
- Create a mounting position and assign it to a component address
- Use the Equipment Information Center
- Equipment structure: errors when assigning mounting positions and levels
Related to