Install, remove and relocate a technical component

  • Updated

Once the history of a technical component has been started, you no longer change its installation location on the card but post every installation, removal and relocation. Each posting creates a technical components ledger entry. This allows you to trace later when a component was installed where. You post in the component journal or with the Connect / Disconnect of a Technical Component wizard.

Prerequisites

Entry types

Entry type Used for Allowed if Assignment afterwards
Start Begin the history without installing the component. Component from, Component Place, Mounting Position and Vehicle No. must be empty. The component does not have a history yet. Unbound
Connect Installation in another technical component (with a Component Place if required), in a mounting position or in a vehicle. If the component does not have a history yet, maintool posts the start automatically. The component is not Bound. Bound
Disconnect Removal. maintool clears the installation location of the component. The component is Bound. Unbound
Reconnect Relocation to a new installation location in one posting (removal and installation). The component is Bound. Bound

Post an installation, removal or relocation in the journal

  1. Search for Technical Component Journals and select the Batch Name if required.
  2. In a new line, check the Posting Date and select the Entry Type.
  3. Enter a Document No. if the journal batch does not have a number series.
  4. Select the Tech. Component No.
    maintool transfers the description, current installation location and dimensions of the component to the line.
  5. Enter the new installation location (for Connect and Reconnect): either Component from and, if required, Component Place, or Mounting Position, or Vehicle No. Clear the fields that do not apply.
    For Disconnect, you do not need an installation location.
  6. If required, select the Work Order No. (show the column if required) if the installation belongs to an order.
  7. Check the lines with Test Report (report Tech. Component Journal - Test).
  8. Choose Post or Post and Print.

Result: maintool posts the technical components ledger entries, changes the installation location on the component card and clears the journal. With Reconnect, two entries are created (Unbound and Bound). The component appears in the equipment structure at the new location.

Post with the wizard

For individual postings without a journal, there is the Connect / Disconnect of a Technical Component wizard (Role Center explorer › Execution › Wizards).

  1. Under What activity should be carried out?, choose Connect, Disconnect or Reconnect.
  2. Enter the no. of the technical component and a description of the activity (both mandatory) and choose Next >.
  3. For Connect and Reconnect: Specify where the component is installed – in another component (with a component place), a mounting position or a vehicle. Choose Next >.
  4. Enter a document no. (mandatory).
  5. Leave Posting on Finish turned on to post immediately. If you turn it off, maintool stores the line in the selected Journal Template to use and Journal Batch to use instead.
  6. Turn on Enter a new activity on Finish if you want to enter the next posting directly.
  7. Choose Finish.

The wizard posts with the work date as the posting date and reports The activity (…) for Technical Component … was successfully posted.

View posted entries

You open the entries of a component on the Technical Component Card with the Ledger Entries action, and the entries of all components of a mounting position on the Mounting Position Card with Technical Component Ledger Entry. Exactly one entry per component is open – it describes the current state. For analyses, see Technical component registers and entries.

Notes and limitations

  • When posting, maintool checks all lines before posting the first one. You therefore cannot disconnect the same component in one line and connect it again in another line of the same posting run. Use Reconnect or two separate postings instead.
  • The posting date must be within the allowed posting period and must not be a closing date.
  • The lookup in the Work Order No. field shows orders with status 200 to 399. For closed orders (status 400), turn on Work Order Revision.
  • Installation, removal and relocation do not create an item posting, even if the component is linked to a spare part (Spare Part FastTab of the Technical Component Card). Post inventory movements separately if required.
  • With Disconnect and Reconnect, maintool transfers the Location Code and Bin Code of the line to the Spare Part FastTab of the component (show the columns if required).
  • If an object monitoring line of the component inherits its counter reading from the parent component, Disconnect removes the inheritance. Reconnect into another component links it again to that component's line with the same monitoring template, see Link a technical object to an object monitoring template.
  • For the rules for component places, see Technical component place.

Related articles

Related to

Was this article helpful?

0 out of 0 found this helpful

Have more questions? Submit a request