Component places are fixed places on a technical component where subcomponents are installed. This lets you map redundant pumps or the four fans of an air conditioning unit, for example, without creating a separate mounting position level. The subcomponents appear in the equipment structure in the order of the component places.

Prerequisites

Settings in the setup

Two fields in the Technical Facility Management Setup (General FastTab) control how component places are used:

Field Values and effect
Bind Component Place Never: When posting a component with Component from, Component Place must be empty.
Optional (default): A component place can be specified but does not have to be.
Always: When posting a component with Component from, Component Place is mandatory.
The check takes place when posting – that is, in the component journal, in the wizard and with Start History.
Assignment of Component Place to Technical Component 1 by 1: A component place holds at most one technical component.
1 by n (default): A component place can hold several components.

Create component places

  1. Open the Technical Component Card of the parent component.
  2. Choose the Component Places action.
  3. Create one line per place:
    • Code (mandatory): identifier of the place, for example L1.
    • Description: text for the place, up to 50 characters.
    • Position: number from 0 to 999. It determines the order of the subcomponents in the equipment structure.
  4. Close the page.

If you later change the Position of a component place, maintool re-sorts the components installed there in the equipment structure.

Assign a component place

How you assign a subcomponent to a component place depends on its Assignment.

Component with assignment Installation

As long as the history of the subcomponent has not been started, you assign the place directly on the card:

  1. Open the Technical Component Card of the subcomponent.
  2. In the Component from field, select the parent component.
  3. In the Component Place field, select one of its component places. The field can only be edited once Component from is filled.

Component with started history

If the Assignment is Bound or Unbound, you can only change the component place by posting with the entry type Connect or Reconnect, see Install, remove and relocate a technical component. This keeps track of when which component was installed in which place.

Result: The subcomponent appears in the equipment structure below the parent component at the position of its component place. The No. of Technical Components column on the Component Places page shows how many components are assigned to a place (show the column if required).

Notes and limitations

  • If possible, set up component places before you start the history of the components, see Start the history of technical components.
  • If you change Component from on the card, maintool clears the Component Place.
  • With 1 by 1, assigning an occupied place displays the message … is not a valid value. (card) or The number of assigned Technical Components from … could not be bigger than 1! (posting).
  • You can only switch to 1 by 1 if no component place has more than one component.
  • You cannot delete a component place as long as components or technical components ledger entries use it.