Operating status for technical objects

  • Updated

For component addresses, mounting positions, technical components and vehicles, you maintain an operating status, for example Operating or Shutdown. maintool records every change. This shows you when and for how long an object was in which status. The status can be passed on automatically to subordinate objects via the equipment structure.

Available from version 20261000.0

Operating status values

Operating status Meaning
Installation The object is being set up or installed. Default value for new objects.
Operating The object is in operation.
Standby The object is ready for operation but not running.
Shutdown The object is temporarily shut down.
Decommissioned The object has been permanently taken out of operation.

The operating status is information only. It does not block postings and has no effect on work orders, work order requests or date proposals. If you want to block an object for these, use the Blocked field.

Change the operating status

  1. Open the card of the component address, mounting position, technical component or vehicle.
  2. On the General FastTab, select the new status in the Operating Status field.

Result: The change applies immediately. maintool closes the previous operating status entry and creates a new one. You cannot enter a different date or a reason. If Pass on Operating Status is turned on, subordinate objects take over the new status (see below).

The operating status is also available as a column in the lists of component addresses, mounting positions, technical components and vehicles. There you can filter for all shut-down objects, for example.

Note for partners:
The operating status and the pass-on settings can be read and changed via the REST API: /api/collana/maintool/v1.0/companies({id})/ with the entities componentAddresses, mountingPositions, technicalComponents and vehicles. operatingStatus, inheritOperatingStatus and passOnOperatingStatus can be changed; id, number, description and lastModifiedDateTime are read-only. Objects cannot be created or deleted via this interface.

Passing on in the equipment structure

Two switches on the General FastTab control the passing on. Both are turned on for new objects.

  • Pass on Operating Status: If the status of the object changes, maintool passes it on to the directly subordinate objects.
  • Inherit from Operating Status: The object takes over the status of its parent object – when the status changes there and when it is placed below a parent object. In each case, the parent object must have Pass on Operating Status turned on.
Parent object Passes on to
Component address Sub-component addresses, assigned mounting positions
Mounting position Technical components installed there, vehicles at this mounting position
Vehicle Technical components of the vehicle
Technical component Subcomponents

The status is passed on across several levels as long as each intermediate level itself has Pass on Operating Status turned on. Example: You set a component address to Shutdown. The assigned mounting position takes over the status and passes it on to the components installed there, and these pass it on to their subcomponents. If a component has Inherit from Operating Status turned off, it keeps its status, and passing on into its branch ends there.

Every change taken over also creates an operating status entry for the subordinate object.

Operating status entries

You open the history of an object on its card with the Operating Status Entries action. The entries show:

  • Object Type and Technical Object No.
  • Operating Status
  • Start DateTime and End DateTime – for the currently valid status, the end is empty
  • Duration – calculated when the entry ends due to a status change
  • User ID of the user who changed the status
  • Entry No. – consecutive per object, starting at 1

When an object is created, maintool creates the first entry automatically. The entries cannot be edited.

Notes and limitations

  • If an object is detached from its parent object or removed, it keeps its current operating status.
  • A mounting position does not take over the status when it is assigned to a component address, but only with the next status change on the component address.
  • When an object is deleted, maintool also deletes its operating status entries.
  • Do not confuse the operating status Installation with the Assignment Installation of a technical component. The Assignment shows whether the history has been started, see Start the history of technical components.

Related articles

Related to

Was this article helpful?

0 out of 0 found this helpful

Have more questions? Submit a request