The Equipment Information Center shows the equipment structure of a component address group as a tree: component addresses with their lower levels, the assigned mounting positions and the technical components and vehicles installed in them. From there, you open the card, entries and documents for each object and create work orders or work order requests. This article describes how to open and use the Equipment Information Center.
Prerequisites
- The Technical Facility Management Setup exists, see Set up technical facility management. If it is missing, maintool cancels opening with an error message.
- At least one component address group exists, and the top-level component addresses are assigned to a group, see Set up master data for technical facility management.
- You have read permission for the technical objects, for example via the Open Equipment Information Center permission set. If permissions are missing, the message There are insufficient read permissions existing for Object … appears.
- If you open the Equipment Information Center from a mounting position that is assigned to component addresses from several groups: a Component Address Group is entered for you in the User Setup.
Open the Equipment Information Center
For a component address group
- Search for Component Address Groups and open the list. In the Maintenance - Workplanner and Maintenance - Worker Role Centers, the Equipment-Informationcenter action (Master Data area) opens the same list.
- Select the group whose structure you want to see.
- Choose the Show Equipment-Informationcenter action.
The Equipment Information Center opens with the structure of this group.
From a technical object
On the cards and lists of component addresses, mounting positions, technical components and vehicles, the Equipment Structure action opens the Equipment Information Center with the structure that contains the object. The action is only available if maintool can determine the group unambiguously:
- Component address: The component address belongs to a Component Address Group.
- Mounting position: The mounting position is assigned to a component address with a group. If it is assigned to component addresses from several groups, maintool uses the Component Address Group from your user setup. If it is missing, maintool shows a notification.
- Technical component and vehicle: maintool determines the group via the mounting position in which the component or vehicle is installed.
Navigate the structure
You find the navigation actions in the Equipment Structure menu:
- Expand All and Collapse All show or hide all levels.
- Expand All from Current Line expands only the levels below the selected object.
- Refresh Curent Line reloads the selected object, for example after you have changed its card.
- Find opens the search in the structure.
Whether pictures of the objects are shown is defined in the Technical Facility Management Setup (Load Pictures in Equipment-Informationcenter field).
Open data for the selected object
Select an object in the structure and choose an action from the Master Data or Transactional Data menu. If no object is selected, the message Please select a Technical Object. appears.
| Menu | Action | What opens |
| Master Data | Card, Statistics, Comments, Data Sheet, Dimensions, Monitoring Lines | The card, statistics, comments, data sheet, default dimensions or object monitoring lines of the selected object. |
| Master Data › Ledger Entries | Technical Component Ledger Entries, Performance Characteristics Ledger Entries | The component ledger entries of a technical component or vehicle, or the performance characteristics ledger entries of the object. |
| Master Data | Component Adresses | For a mounting position, technical component or vehicle: the component addresses to which the related mounting position is assigned. |
| Master Data | Technical Components | For a mounting position or vehicle: the technical components installed directly in it. |
| Master Data | Pictures, Work Notices, Instructions, Component Places, Technical Component BOM | Only for technical components: pictures, work notices, instructions, component places or bill of materials of the component. |
| Transactional Data | Requests, Work Orders, Feedbacks | Open work order requests, work orders (status Planning up to before Closed) and work order feedback in which the object is entered as a detail. |
| Transactional Data | Pos. Requests, Closed Work Orders, Pos. Feedbacks | Posted work order requests, closed work orders and posted work order feedback with the object. |
Start activities
- Create new Activity › Create Work Order or Create Work Order Request creates a work order or work order request for the selected object. How this works is described in Create a work order from the Equipment Information Center.
- Start History starts the history for a selected technical component with the assignment Installation, see Start the history of technical components.
- Search for Technical Specifications opens the search across the values of the data sheets; the Type is preset to the object type of the selected object. See Search for technical specifications.
Notes and limitations
- maintool caches the structure of each group and updates it in the background when changes are made. If an object that you have just created or moved is missing, rebuild the cache in the Component Address Groups list with Rebuild EIC Cache, see Set up master data for technical facility management.
- The Equipment Information Center remembers your view per user. With User › Reset User-Defined Layout, you restore the default view. After the confirmation, you must reopen the Equipment Information Center.
Related articles
- Technical facility management overview
- Plan the equipment structure
- Create a work order from the Equipment Information Center
- Set up master data for technical facility management