Posted performance characteristic ledger entries cannot be changed or deleted. You undo an incorrectly posted value with the posting type Reverse Value and then post the correct value. This applies to the types of monitoring Counter and Attrition / Consumption.
Prerequisites
- The value to be corrected is the last posted value of the object monitoring line. You reverse older values step by step (see below).
Reverse the last value and post it correctly
- Open Performance Characteristic Journals and select the Batch Name.
- In a new line, select the Posting Type Reverse Value.
- Select Type, No. and Line No. (Object Monitoring Line).
maintool enters the last posted value as the Actual Value – exactly this value is reversed. Do not change it. - Check Posting Date and Document Date. maintool does not copy them from the reversed entry.
- Post the line.
- Then post the correct value with Post Value (or with Change Value if the reversed entry was posted with Change Value). See Record and post performance characteristics in the journal.
Result: maintool posts an offsetting entry with a negative value and applies it to the reversed entry (Applies-to Entry, Closed-by Entry). The value before it is the current value of the object monitoring line again (Open = Yes). If another line inherits the counter reading, maintool reverses its entry as well.
Reverse several values
maintool always reverses only the last posted value. If the error is, for example, three postings back:
- Reverse the last value as described above and post the line.
- Create a new line with Reverse Value. maintool now suggests the value posted before. Post this line as well.
- Repeat this until the incorrect value is reversed.
- Then post the correct value and the later values again.
Enter the reversals one after the other and post each one individually. maintool determines the suggested value when you enter the line – several reversal lines for the same object monitoring line that you create together before posting all suggest the same value.
Example: fill level of an oil tank
Object monitoring line with the type of monitoring Attrition / Consumption, Initial Value 100 liters. The last posted fill level is 100 liters.
| Situation | Posting | Current fill level afterwards |
| 22.5 liters consumed, indicator shows 77.5 liters | Post Value, Actual Value 77.5 | 77.5 |
| Error: it was 25 liters, the indicator showed 75 liters – first reverse … | Reverse Value (maintool suggests 77.5) | 100 |
| … then post correctly | Post Value, Actual Value 75 | 75 |
| Tank refilled by 20 liters, indicator shows 95 liters | Change Value, New Value 95 | 95 |
| Error: only 2 liters were refilled, indicator shows 77 liters – first reverse … | Reverse Value (maintool suggests 95) | 75 |
| … then post correctly | Change Value, New Value 77 | 77 |
Post refilling with Change Value so that it is not included in the total value as consumption.
Notes and limitations
- For Threshold / Range, Reverse Value and Change Value are not possible. Post the correct measured value with Post Value; the last posted value is the current value.
- If you posted an increase for several lines with a Monitoring Template Code, reverse it the same way: Reverse Value with the same monitoring template code reverses the last value of each object monitoring line of the object with this template.
- With the Import Object Monitoring Lines function and the Default Entry Type Reverse Value, you create reversal lines for many lines at once, see Import object monitoring lines into the journal.
Related articles
- Record and post performance characteristics in the journal
- Import object monitoring lines into the journal
- Performance characteristics – overview
Related to