Record and post performance characteristics in the journal

  • Updated

In the performance characteristic journal, you record counter readings, measured values and fill levels of individual technical objects and post them as performance characteristic ledger entries. For many objects at once, use the Import Object Monitoring Lines function; for values from a work order, use a checklist (see Related articles).

Prerequisites

  • The object has an object monitoring line with a template code, see Link a technical object to an object monitoring template. The Status of the line is not Blocked or Deleted.
  • The object is not blocked.
  • For Attrition / Consumption: an Initial Value is entered in the object monitoring line.

Record and post performance characteristics

  1. Search for Performance Characteristic Journals and open the page. If there are several journal templates, select one.
  2. In the Batch Name field, select the journal, for example the default journal.
  3. In the new line, check Posting Date and Document Date. maintool suggests the work date; if you change the posting date, maintool copies it to the document date. The Document No. comes from the number series of the journal batch if one is specified there.
  4. Leave the Posting Type at Post Value.
  5. In the Type field, select Component Address, Technical Component or Vehicle, and in the No. field the object.
  6. In the Line No. (Object Monitoring Line) field, select the object monitoring line.
    maintool enters the last posted value as the Actual Value. At the bottom of the page, you see the description of the object and the line as well as the dates, Actual Value and Total Value of the last posting.
  7. In the Actual Value field, enter the value you read.
  8. Choose Post and confirm the question Do you want to post the journal lines?

Result: maintool posts a performance characteristic ledger entry and deletes the line from the journal. If another line inherits the counter reading, an additional entry is created for it. You see the posted values in the Performance Characteristic Ledger Entries – from the card of the object or in the object monitoring lines with Object Monitoring Line › Ledger Entries. The entry with the current value has Open = Yes.

What applies per type of monitoring

Counter

  • Record the counter reading. maintool calculates the Total Value from the increase.
  • A reading lower than the last one is only possible if an Ultimate Value is specified in the object monitoring line. maintool then assumes a counter overflow. Example: ultimate value 9,999, last reading 9,950, new reading 120 – the total value increases by 170. Without an ultimate value, maintool reports that the actual value must not be smaller than the last value.
  • maintool rejects a reading above the ultimate value.

Threshold / Range

  • Record the measured value. Only the posting type Post Value is allowed; maintool rejects Change Value and Reverse Value with a message about the type of monitoring.

Attrition / Consumption

  • Record the current remaining value as a positive number, for example the fill level in liters. maintool adds up the consumption in the Total Value.
  • maintool rejects a value above the Initial Value.
  • After refilling or replacing, set the new value with Change Value (see below).

Post an increase for several lines

If you have several object monitoring lines with the same template for the same counter (for example for maintenance after 2,000 and 5,000 operating hours) and have not set up inheritance, post the increase for all of them in one line:

  1. Show the Monitoring Template Code column using Personalize.
  2. Fill in Type and No. and leave Line No. (Object Monitoring Line) blank.
  3. In the Monitoring Template Code field, select the template. The selection shows the counter templates of the object.
  4. In the Actual Value field, enter the increase since the last posting, for example 150 hours, and post.

Result: maintool posts an entry for each object monitoring line of the object with this template: last reading of the line plus the increase. Line No. (Object Monitoring Line) and Monitoring Template Code are mutually exclusive; with a monitoring template code, only Post Value and Reverse Value are possible.

Set a new value: Change Value

With Change Value, you set a new starting value without the jump being included in the total value – for example after replacing a counter or refilling a tank.

  1. Show the columns New Value, New Total Value and New Ultimate- resp. Initial Value using Personalize.
  2. Select the Posting Type Change Value and the object monitoring line. maintool enters the last value as the Actual Value and the last total value as the New Total Value. As the New Value, maintool suggests 0 for counters and the Initial Value for attrition / consumption.
  3. In the New Value field, enter the new reading, for example 0 for a new counter or 95 liters after refilling.
  4. If the new counter has a different ultimate value or the tank a different initial value, enter it in the New Ultimate- resp. Initial Value field. maintool copies it to the object monitoring line when posting. The new value must not exceed it.
  5. Post the line.

Result: maintool posts two entries: one with the previous value (Open = No) and one with the new value. The total value remains; later postings count from the new value. An example with all posting types is in Correct posted performance characteristics.

Post counter readings with an earlier date

If the Document Date of a counter reading is before the document date of the current value, maintool automatically marks the line as Historical Value. This way you can add readings you missed:

  • The value must be greater than the last reading before this date and smaller than the first reading after it. Otherwise, maintool reports the range in which the value must lie.
  • maintool posts the entry with Open = No. The current value of the object monitoring line does not change.

Notes and limitations

  • If you post the same value and total value as last time with Post Value, maintool asks: You did not change any values. Do you want to continue posting?
  • Negative values are not possible.
  • The posting date must be within the allowed posting period (Allow Posting From / Allow Posting To of the user, otherwise from the General Ledger Setup).
  • The lines remain in the journal until you post; Post posts all lines of the journal. Use Posting › Test Report... to check the lines before posting.
  • Correct incorrectly posted values with Reverse Value, see Correct posted performance characteristics.