With the Import Object Monitoring Lines function, maintool creates lines in the performance characteristic journal for many object monitoring lines at once. You then only enter the values you read and post everything in one step – for example after an inspection round with a list of counter readings.
Prerequisites
- The objects have object monitoring lines with a template code, see Link a technical object to an object monitoring template.
Import object monitoring lines
- Open Performance Characteristic Journals and select the Batch Name.
- Choose Function › Import Object Monitoring Lines. The Import Object Monitoring Lines into Performance Characteristics Journal page opens.
- On the Options FastTab, specify what is imported:
- Default Entry Type – Post Value or Reverse Value for all new lines.
- Object Monitoring Template Code – only lines with this template, for example only the operating hours counters. Blank = all templates.
- Object Monitoring Lines without Inheritance – lines that inherit their value from another line are not imported. maintool posts their value via the inheritance anyway.
- Component Addresses Only, Technical Components Only or Vehicles Only – only lines of this object type. You can only select one of these options.
- If required, narrow down the objects further on the filter FastTabs, for example technical components by Component Group.
- Choose OK.
- Check the new lines and enter the value you read in the Actual Value field of each line. Delete lines for which you have no value.
- Choose Post and confirm the question.
Result: maintool creates one journal line per matching object monitoring line – with the work date as posting and document date, the document number from the number series of the journal batch and the last posted value as the Actual Value. After posting, the lines are deleted from the journal.
What is imported
- Only object monitoring lines with the types of monitoring Counter, Threshold / Range and Attrition / Consumption – no lines with Date.
- No lines with the Status Blocked or Deleted.
- No blocked objects.
- Without options and filters, maintool imports all object monitoring lines of all component addresses, technical components and vehicles that meet these conditions.
Notes and limitations
- If you post an imported line unchanged with Post Value, maintool asks (except for Threshold / Range) whether you want to post anyway (You did not change any values …). Therefore delete lines without a new value before posting.
- The same rules apply to the lines as for individual recording, for example for counter overflow and thresholds, see Record and post performance characteristics in the journal.
- Define clear characteristics (for example a template or component group) for the objects that you regularly record together. Then one filter is enough to import exactly these objects.
Related articles