An object monitoring template defines which kind of performance characteristics you record for technical objects – for example operating hours or a fill level. Set up the template before you assign it to an object. You can assign a template to any number of objects.
Examples
| Type of monitoring | Examples |
| Counter | A technical component has an operating hours counter. A vehicle has an odometer. A component address has a switching cycle counter. |
| Threshold / Range | A technical component has a humidity sensor. A vehicle has oil pressure monitoring. A component address has a measuring device for the room air. A condition is recorded as 0 / 1. |
| Attrition / Consumption | A technical component has a fill level indicator on an oil tank. A vehicle has a fuel tank. The remaining thickness of a brake pad is measured on a test bench. |
For Attrition / Consumption, you always record the current remaining value as a positive number later (for example the fill level in liters), not the quantity consumed.
Create an object monitoring template
- Search for Object Monitoring Templates and open the page.
- Choose New. The Object Monitoring Template Card page opens.
- In the Code field, enter a unique code (up to 10 characters), for example
Z4711. - In the Description field, enter a description (up to 50 characters), for example "Pump operating hours".
- In the Type of Monitoring field, select Counter, Threshold / Range or Attrition / Consumption. The default is Counter.
- Fill in the other fields if required (see below).
Result: The template is available in the Template Code field of the object monitoring lines. To record performance characteristics, Code, Description and Type of Monitoring are sufficient.
Other fields
| Field | Meaning |
| Time Schedule No. | Time schedule that maintool copies to the object monitoring line when you enter the template code there. The time schedule must have the Type Object Monitoring Template. Leave the field blank if the template is only used for recording or if different time schedules apply per object – you can then enter the time schedule in the object monitoring line. |
| Action by Value | Editable only for Threshold / Range: default for the field of the same name in the object monitoring line (Minimum Value, Maximum Value or Both). It only takes effect together with a time schedule, see Set up threshold monitoring with an activity. |
| Unit of Measure Code | Unit of the values, for example hours or liters. |
| Component Address Group | Narrows down the selection: on the card of an object monitoring line of a component address, maintool only offers templates of this group and templates without a group. |
| Component Group, Classification, Type, Construction Type | Narrow down the selection for technical components: maintool only offers templates whose values match the component or are blank. |
| Actual Value Caption | Caption of the Actual Value field on the card of the technical component or vehicle if a line with this template is selected there as Value Line No. (Object Monitoring Line). maintool suggests a text per type of monitoring, for example Actual Counter Value; you can overwrite it, for example with "Operating hours". |
Component Address Group and the fields Component Group, Classification, Type and Construction Type are mutually exclusive. If a component address group is entered, the other four fields are disabled, and vice versa.
Notes and limitations
- The type of monitoring Date can also be selected in the template. It works without performance characteristics, using only a time interval, and belongs to appointment management.
- maintool copies Type of Monitoring, Time Schedule No., Action by Value, Unit of Measure Code and Description to the object monitoring line at the moment you enter the template code there. Later changes to the template do not change existing object monitoring lines.
- A counter or consumption value that is to trigger activities is not set up in the time schedule but always in the object monitoring line on the technical object.