To post performance characteristics for a technical object, create an object monitoring line with an object monitoring template on the object. This is possible for component addresses, technical components and vehicles. You can assign any number of object monitoring lines to an object, including several with the same template.
Prerequisites
- The object monitoring template exists. See Set up object monitoring templates.
- The technical object is not blocked.
Create an object monitoring line
Example: The technical component "Pump 4711" has an operating hours counter. It is linked to the template Z4711 (type of monitoring Counter).
- Open the card of the object, for example from the Technical Components list.
- Choose the Monitoring action. The Object Monitoring Lines page shows the existing lines of the object.
- Create a new line and select the template in the Template Code field.
maintool assigns the Line No. and copies Type of Monitoring, Description, the unit and – if specified in the template – the Time Schedule No. - Open the card of the line with Object Monitoring Line › Card. Besides General, the Object Monitoring Line - Card page has one FastTab each for Date, Counter, Threshold / Range and Attrition / Consumption. Only the fields of the line's type of monitoring are editable.
- On the General FastTab, decide on the Time Schedule No. field:
- blank – the line is only used to record performance characteristics,
- with a time schedule – maintool suggests activities such as maintenance or cleaning based on the performance characteristics (see Related articles).
- Fill in the FastTab of the type of monitoring (see below).
Result: The line can be selected in the performance characteristic journal in the Line No. (Object Monitoring Line) field.
Settings per type of monitoring
Counter
- Ultimate Value – the highest reading the counter can display, for example 9,999 for a four-digit counter. With an ultimate value, maintool detects a counter overflow: if a new reading is lower than the last one, maintool assumes that the counter has started again at 0. Without an ultimate value, maintool rejects a lower reading with a message – this way, typing errors are noticed. Therefore only enter the ultimate value if the counter can reach it.
- Interval, Initial Value and Tolerance Value are only editable if the line has a time schedule. They control when an activity becomes due, see Set up counter and consumption monitoring with an activity.
- Inherit Actual Value from Type, … No. and … Line No. – see "Inherit counter readings".
Threshold / Range
All fields of the FastTab are only editable if the line has a time schedule. Without a time schedule, you only record measured values. You set up thresholds and the reference value in appointment management, see Set up threshold monitoring with an activity. There is no inheritance for this type of monitoring.
Attrition / Consumption
- Initial Value – the value when new or when the tank is full, for example 100 liters. Without an initial value, you cannot post performance characteristics for the line. For the posting type Change Value, maintool suggests the initial value as the New Value.
- Interval, Critical Value and Tolerance Value are only editable if the line has a time schedule, see Set up counter and consumption monitoring with an activity.
- There is no inheritance for this type of monitoring.
Inherit counter readings
If, for example, a machine has an operating hours counter, a subordinate component can take over its reading. You then only post the counter reading of the machine; maintool transfers the increase to the inheriting lines. This only applies to the type of monitoring Counter.
- Open the card of the object monitoring line that is to take over the value and go to the Counter FastTab.
- For technical components only: in the Inherit Actual Value from Type field, select Technical Component or Vehicle. If the component is installed in a vehicle, maintool suggests Vehicle. Component addresses inherit from component addresses, vehicles from vehicles.
- Open the selection in the Inherit Actual Value from No. field. It shows the object monitoring lines with the same template code from which the line can inherit. Select a line.
maintool fills in Inherit Actual Value from No. and Inherit Actual Value from Line No.
Result: Every posting that increases the counter reading of the passing-on line, and every reversal, creates an additional ledger entry for each inheriting line. A line cannot inherit from itself. If an inheriting line has the Status Blocked, the posting on the passing-on line stops with a message about the status.
Show the actual value on the card of the object
On the card of a technical component and of a vehicle, select a line with the type of monitoring Counter, Threshold / Range or Attrition / Consumption in the Value Line No. (Object Monitoring Line) field. The Actual Value field then shows the current value of this line, captioned with the Actual Value Caption of the template.
Notes and limitations
- You can only enter a template code as long as the line does not have a Time Schedule No. yet.
- maintool rejects an Ultimate Value below the current counter reading.
- Lines with the Status Blocked or Deleted cannot be selected in the performance characteristic journal, and maintool does not import them. Use the status, for example, to exclude the line of an object that no longer exists from recording.
- An object monitoring line with performance characteristic ledger entries cannot be deleted. maintool then reports that ledger entries already exist.
- You cannot record performance characteristics for mounting positions.
Related articles
- Record and post performance characteristics in the journal
- Performance characteristics – overview
- Set up counter and consumption monitoring with an activity
- Set up threshold monitoring with an activity